top of page
AN1071-Humidichip-8797-1.jpg.webp

AN1071 Humidichip RH Stabilizer


Designed specifically for use with Andersen Anprolene and EOGas Sterilizer Systems, this unique device ensures adequate Relative Humidity (RH) within the sterilization bag during the sterilization cycle. Each single-use pre-moistened 2″ x 2″ Humidichip releases up to 4 grams of water vapor. Employ Humidchip with a Humiditube in each sterilization cycle.

  • Ensures RH requirements for sterilization are met

  • Prevents oversaturation

 

​      25/pouch                                          Pack type: pouch        Unit of Measure: 25 count                           Case qty: 1

​

AN1072-humiditube-8801.jpg.webp

AN1072 Humiditube

​

The AN1072 Humiditube developed to hold the Humidichip during the sterilization cycle, allows air to circulate around the chip – ensuring appropriate Relative Humidity. The Humiditube is reusable.

Note: The EOGas 4 has an alternate method for holding the Humidichip.

​

       1 unit                                                     Pack type: each

       Unit of Measure: 1 count                            Case qty: 1

​

AN87 Dosimeter

Time, temperature and EO concentration are essential to successful sterilization. Dosimeter chemical integrators give visual assurance that all these parameters have been fulfilled. Place in the least accessible place in the load for gas to reach (in the core or center of the load).

Dosimeters change color in proportion to the dose of sterilant they contact. View results immediately after sterilization.

The blue line must pass the triangle for the cycle to be considered a success. No laboratory culture is necessary. Use one Dosimeter per cycle. (Not a BI substitute). For use with Andersen Anprolene sterilizers.

  • Read results immediately

  • Reliable

  • Easy to use for every sterilization load

       25/box                                 Pack type: box

       Unit of Measure: 25 count

       Case qty: 1

AN85-product.webp

AN85 Exposure Indicator

​

Know at a glance which packs have been processed! The AN85 Exposure Indicator is an FDA-cleared, single-use Class or Type 1 process indicator used to distinguish between processed and unprocessed packaged medical devices ― through a visible color change from yellow-green to blue after exposure to EO. Convenient self-stick backing adheres to paper, cloth or plastic wrapping. Use one label for each item.

  • Easy to use

  • Verifies exposure for each pack within the load

  • Convenient packaging

.

​     200/box                                                     Pack type: box

    Unit of Measure: 200 count                            Case qty: 1

AN2203 EZTest Biological Indicator

​

Self-contained Biological Indicators (BI’s) provide sterility assurance for EO cycles. EZTest contains a high population (106) of B. athrophaeus ― sterilization-resistant bacterial spores ― on a filter-paper carrier packaged within a small, thermoplastic culture tube.

Inside the thermoplastic culture tube is a sealed-glass ampoule of specially formulated soybean casein digest culture medium containing a color indicator which turns a dramatic yellow if spores grow. Color change reveals test results after 48 hours incubation at 37°C.

​

     25/box                                                      Pack type: box

    Unit of Measure: 25 count                              Case qty: 1

AN2205-BI-Incubator-8804.jpg (1).webp

AN2205 13-Well Incubator for BIs

​

​Thirteen (13) individually numbered incubation cavities for self-contained biological indicators.

Integrated thermometer for easy temperature reference. Three temperature settings: 37°C for EO Gas, 57°C for steam, & 60°C for EZTest 10-hour biological indicators for steam.

Activation cavity for activating crushable self-contained biological indicators.

International Power supply, with interchangeable blades for US, UK, Europe, & Australia.

This unit works with EZTest AN2203 BIs.

​

     1 Unit                                                      Pack type: box

    Unit of Measure: each                              Case qty: 1

An5100.png

AN5100 Abator Cartridge

​

Andersen abators are a simple, cartridge-based system designed to remove more than 99% of the ethylene oxide emitted from 200 EO ampoules/cartridges.

​

Replaceable 5100 Abator Cartridges employ a dry catalyst resin that converts ethylene oxide to biodegradable organic compounds. For use with Anprolene or EOGas 4 sterilizers.

​

The AN5100 Abator Cartridge is utilized within the AN5100 Abator cabinet (sold separately) which is controlled and monitored through a single wire connection to the sterilizer. Sterilizer will automatically alert the operator when it is nearing time to change the cartridge.

​

​     1 Unit                                                      Pack type: box

    Unit of Measure: 1                                  Case qty: 1

AN5100-Abator.png.webp

AN5100 EO Abator Cabinet 

​

The AN5100 EO Abator is designed to remove more than 99% of the ethylene oxide emitted from our Anprolene or EOGas 4 sterilizers. 

The abator employs a dry catalyst resin that converts ethylene oxide to biodegradable organic compounds.

Our systems are recognized for using a microdose of ethylene oxide and our emissions fall well below all federal guidelines. If you choose to abate, remember we have this option for you.

​

​     1 Unit                                                      Pack type: box

    Unit of Measure: 1                                  Case qty: 1

Contact Us

We'd love to help!

Unit 3/14 Lionel Road, Mt Waverley,

Victoria 3149, AUSTRALIA

+61 (03) 9543 3991

Thanks for submitting!

Steriflex is the exclusive distributor in Australia for:
Andersen Sterilizers logo

©2025 by Steriflex. Proudly created with Wix.com

bottom of page